Register for email alerts and news feeds:
This journal | BMJ Group
rss
Journal of Epidemiology and Community Health 2006;60:829-835; doi:10.1136/jech.2005.041707
Copyright © 2006 by the BMJ Publishing Group Ltd.

EVIDENCE BASED PUBLIC HEALTH POLICY AND PRACTICE

Waterborne diseases prevention: evaluation of inspection scoring system for water sites according to water microbiological tests during the Athens 2004 pre-Olympic and Olympic period

Christos Hadjichristodoulou1,2, Varvara Mouchtouri1,2, Anastasia Vousoureli2, Athanasios Konstantinidis1, Philipos Petrikos2, Emmanuel Velonakis2, Panagiota Boufa3, Jenny Kremastinou2

1 University of Thessaly, Faculty of Medicine, Department of Hygiene and epidemiology, Larisa, Greece
2 National School of Public Health, Olympic Planning Unit, Athens, Greece
3 Central Public Health Laboratory, Athens, Greece

Correspondence to:
Correspondence to:
Professor C Hadjichristodoulou
Faculty of Medicine, University of Thessaly, 22 Papakiriazi Str, Larisa, 41222, Greece; xhatzi{at}med.uth.gr

Study objectives: To evaluate the inspection grading system for water sites implemented during the Athens 2004 Olympic inspection programme.

Design: The relation between the standardised inspections results of 716 water supply systems and 289 public swimming pools, and microbiological test results of 2358 samples collected during inspections was examined.

Setting: Athens, Thessaloniki, Patra, Volos, and Iraklio, Greece. Inspections and sampling conducted during a two year period before the 2004 Olympics.

Main results: Swimming pools unsatisfactory inspection grading results were significantly associated with positive water microbiological test results (relative risk = 2.5, p<0.05). One of the six violations of swimming pools and five of the seven violations of water supply systems designated as "critical" water safety hazards in the inspection reports were significantly associated with positive microbiological test results. The receiver operating characteristic analysis identified the unsatisfactory score designed in the swimming pools standardised inspection report, as the ideal score (–15), in adequately producing positive microbiological test results (sensitivity 13.2%, specificity 89%).

Conclusions: This study shows the utility of standardised inspection grading systems in waterborne diseases prevention planning and implementation strategies of policy makers and regulators. Future water quality assessment should be based on the implementation of a robust standardised inspection system and reduce the need of microbiological tests.

Keywords: inspection; swimming pool; Olympic Games


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

In this issue
Carlos Alvarez-Dardet, John R Ashton
J Epidemiol Community Health 2006 60: 825. [Extract] [Full Text] [PDF]

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

BMJ Careers - Latest infectious diseases and epidemilogy jobs

Infectious diseases and epidemilogy jobs